PA Rigging / L-Acoustics / K3 / Rigging a Kara II Downfill Array with KARA-DOWNK3
K3 — Rigging a Kara II Downfill Array with KARA-DOWNK3
Connecting a Kara II downfill array to the bottom of a flown K3 array using KARA-DOWNK3. Reference: LA-K3-KARA-DOWNFILL-01. Follow in order — this is a sequential rigging procedure, not an independent checklist; steps depend on the ones before them.
- Minimum 2 operators.
- Flown K3 + Kara II downfill: safe limit 12 K3 + 6 Kara II / maximum 18 K3 + 6 Kara II.
- Do not implement a pullback on a K3 array with a Kara II downfill.
- This procedure also applies to the original Kara (not just Kara II) — refer to the Kara II owner's manual as a complement.
- Prerequisites: a K3 array is prepared and raised; an array of three Kara II with 0° inter-enclosure angles is prepared and positioned under the K3 array; confirm the latches on the bottom K3 are in storage position.
0/ complete
Not saved anywhere — resets when you leave this page.
Rigging the Downfill
Source: L-Acoustics K3 Owner's Manual, EN, v4.1. Rigging procedures, pp.84-87.